Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Arq. bras. cardiol ; 101(5): 410-417, nov. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-696894

ABSTRACT

FUNDAMENTO: A estimulação crônica do ventrículo direito (EVD) induz um padrão de contração dessincronizado, produzindo assincronia interventricular e intraventricular. Muitos estudos têm mostrado a relação entre EVD e a forma e função ventricular esquerda (VE) comprometida. OBJETIVO: O objetivo deste estudo foi avaliar a sincronia e a função do VE em pacientes pediátricos que receberam EVD em comparação com aqueles que receberam estimulação do VE (EVE). MÉTODOS: As funções sistólica e diastólica e a sincronia do VE foram avaliadas em 80 pacientes pediátricos com bloqueio atrioventricular total não cirúrgico ou pós-cirúrgico, com estimulação a partir do endocárdio do ventrículo direito (VD) (n = 40) ou do epicárdio do VE (n = 40). Foram analisados dados ecocardiográficos obtidos antes da implantação do marca-passo, imediatamente após a implantação, e no final de um acompanhamento médio de 6,8 anos. RESULTADOS: A função diastólica do VE não se alterou em nenhum dos pacientes durante o acompanhamento. A função sistólica ventricular esquerda foi preservada nos pacientes que receberam EVE. No entanto, a fração de encurtamento e a fração de ejeção diminuíram de medianas de 41% ± 2,6% e 70% ± 6,9% antes da implantação para 32% ± 4,2% e 64% ± 2,5% (p < 0,0001 e p < 0,0001), respectivamente, no acompanhamento final. O atraso mecânico interventricular foi significativamente maior com a EVD (66 ± 13 ms) do que com a EVE (20 ± 8 ms). Da mesma forma, nos dois grupos houve uma diferença significativa entre os seguintes parâmetros: atraso mecânico do VE (EVD: 69 ± 6 ms, EVE: 30 ± 11 ms, p < 0,0001); atraso septo-lateral (RVP: 75 ± 19 ms, LVP: 42 ± 10 ms, p < 0,0001) e atraso septo-posterior (EVD: 127 ± 33 ms, EVE: 58 ± 17 ms, p < 0,0001). CONCLUSÃO: Quando comparado ao endocárdio do VD, o epicárdio do VE é um local ideal para a estimulação para preservar a sincronia e a função cardíaca.


BACKGROUND: Chronic right ventricular pacing (RVP) induces a dyssynchronous contraction pattern,producing interventricular and intraventricular asynchrony. Many studies have shown the relationship of RVP with impaired left ventricular (LV) form and function. OBJECTIVE: The aim of this study was to evaluate LV synchrony and function in pediatric patients receiving RVP in comparison with those receiving LV pacing (LVP). METHODS:LV systolic and diastolic function and synchrony were evaluated in 80 pediatric patients with either nonsurgical or postsurgical complete atrioventricular block, with pacing from either the RV endocardium (n = 40) or the LV epicardium (n = 40). Echocardiographic data obtained before pacemaker implantation, immediately after it, and at the end of a mean follow-up of 6.8 years were analyzed. RESULTS: LV diastolic function did not change in any patient during follow-up. LV systolic function was preserved in patients with LVP. However, in children with RVP the shortening fraction and ejection fraction decreased from medians of 41% ± 2.6% and 70% ± 6.9% before implantation to 32% ± 4.2% and 64% ± 2.5% (p < 0.0001 and p < 0.0001), respectively, at final follow-up. Interventricular mechanical delay was significantly larger with RVP (66 ± 13 ms) than with LVP (20 ± 8 ms). Similarly, the following parameters were significantly different in the two groups: LV mechanical delay (RVP: 69 ± 6 ms, LVP: 30 ± 11 ms, p < 0.0001); septal to lateral wall motion delay (RVP: 75 ± 19 ms, LVP: 42 ± 10 ms, p < 0.0001); and, septal to posterior wall motion delay (RVP: 127 ± 33 ms, LVP: 58 ± 17 ms, p < 0.0001). CONCLUSION: Compared with RV endocardium, LV epicardium is an optimal site for pacing to preserve cardiac synchrony and function.


Subject(s)
Adolescent , Child , Female , Humans , Male , Cardiac Resynchronization Therapy/methods , Electroencephalography Phase Synchronization/physiology , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left/physiology , Atrioventricular Block/therapy , Biopsy/methods , Endocardium/pathology , Logistic Models , Pacemaker, Artificial , Prospective Studies , Pericardium/pathology , Treatment Outcome , Ventricular Dysfunction, Left/therapy
SELECTION OF CITATIONS
SEARCH DETAIL